General Attributes - Intergraph Smart Reference Data Standard Database - Version 12.1 - Help - Hexagon PPM

Standard Database for Intergraph Smart Reference Data Hangers and Supports Help

Language
English
Product
Intergraph Smart Reference Data Standard Database
Search by Category
Help
Standard Database for Smart Reference Data Version
12.1

Braced Box Frame support uses all the General Attributes specified in Common Attributes section and the following additional general attributes:

Attribute Name

Description

Implementation Details

IJUAhsSupportNumber::SupportNumber

The support detail number as specified on the support specification. This value will be used by the default BOM function when generating the BOM Description for the support.

IE: BoxFrame-01

IJUAhsSteelStandard::SteelStandard

A code list value that defines the steel standard used by the support. If external rules were written to select the steel standard, this attribute would be used to determine the standard to use.

hsSteelStandard:

5 – Euro

10 – AISC

15 – CISC and so on.

IJUAhsFrameType::

FrameType

A code list value that defines the type of the frame shape.

hsFrameType:

6 - Box Frame

7 – Braced Box Frame

IJUAhsFrameOrientation:: FrameOrientation

A code list value that defines the frame support orientation with respect to the supporting object or the global coordinate system.

hsFrameOrientation:

1 - Direct towards the supporting object

2 - Orthogonal to the global coordinate system

3 - Tangent to the first and last selected pipes

IJUAhsFrameConfiguration:: rameConfiguration

Defines the initial frame configuration on placement. This property is applicable only to U, L and T-Frames types. You can change the configuration after placing the support by clicking Change Support Configuration on the ribbon.

Accepted values are:

1 - Frame support placed on the far side of the pipe.

2 - Frame support placed on the closest side of the pipe.

IJUAhsMirrorFrame:: MirrorFrame

Mirrors the frame support about the bounding box.

0 - False

1 - True

IJUAhsIncludeInsulation:: IncludeInsulation

Specifies whether the frame should adjust its size to include pipe insulation.

0 - False

1 - True

IJUAhsStructureConn:: StructureConnection

A code list value that specifies how the hanger beam part is connected to the structure.

1 - Normal

2 - Lapped

3 - Lapped-Opposite