A Pipe to Pipe support uses the following attachments:
Name |
User Name |
Category |
On Property Page |
Read Only |
---|---|---|---|---|
ShearLugPart |
Shear Lug Part |
Standard |
Yes |
Yes |
ShearLugPartRule |
Shear Lug - Rule |
Standard |
No |
Yes |
ShearLugPartDefinition |
Shear Lug - Definition |
Standard |
No |
Yes |
ShearLugPartSelection |
Shear Lug - Selection |
Standard |
No |
Yes |
PipeAttPart1 |
Pipe Attachment 1 |
Standard |
Yes |
Yes |
PipeAttPart1Rule |
Pipe Attachment 1 - Rule |
Standard |
No |
Yes |
PipeAttPart1Definition |
Pipe Attachment 1 - Definition |
Standard |
No |
Yes |
PipeAttPart1Selection |
Pipe Attachment 1 - Selection |
Standard |
No |
Yes |
PipeAttPart2 |
Pipe Attachment 2 |
Standard |
Yes |
Yes |
PipeAttPart2Rule |
Pipe Attachment 2 - Rule |
Standard |
No |
Yes |
PipeAttPart2Definition |
Pipe Attachment 2 - Definition |
Standard |
No |
Yes |
PipeAttPart2Selection |
Pipe Attachment 2 - Selection |
Standard |
No |
Yes |
Attribute Name |
Description |
Implementation Details |
---|---|---|
IJUAhs_ShearLugPart:: |
Specifies the Shear Lug part number or part class to use for the support. |
Specify the part number. Alternatively, specify the part class. You can only place Shear Lugs on vertical perpendicular pipes only. |
IJUAhs_ShearLugPartDef:: |
Specifies the number of Shear Lugs to place. |
0 - None 1 - Vertical pipe (perpendicular configuration) |
IJUAhs_PipeAttPart1:: IJUAhs_PipeAttPart2:: |
Specifies the pipe attachment part number or part class to use for the support. |
You can use any support component with a route port as a pipe attachment. Some common pipe attachments include U-Bolts and Shoes. |
IJUAhs_PipeAttPart1Def:: |
Determines the pipes to which PipeAttPart1 is attached. |
0 - None 1 - First selected pipe 2 - First two selected pipes 3 - First three selected pipes 4 - Outside pipes |
IJUAhs_PipeAttPart2Def:: |
Determines the pipes to which PipeAttPart2 is attached. The software attaches PipeAttPart2 to pipes after placing all PipeAttPart1 attachments. For example, if PipeAttPart1 and PipeAttPart2 are set to 2, the software attaches PipeAttPart1 to the first two selected pipes. The software attaches PipeAttPart2 to the next two selected pipes. Subsequent pipes receive no pipe attachments. If too few pipes are selected, the software places the pipe attachment on as many pipes as possible. |
0 - None 1 - First selected pipe 2 - First two selected pipes 3 - First three selected pipes 4 - All remaining pipes The software applies PipeAttPart2 after using all PipeAttPart1 components. |
IJUAhs_Insulation:: |
Specifies the insulation part number or part class to use for the support. |
Specify the part number. Alternatively, specify the part class. |
IJUAhs_InsulationRl:: |
Specifies a hgrSupportRule that returns an insulation part number. The hanger rule must be the name of an existing rule in the catalog. |
Examples: Rule Name: PipeAttByPipeSize Rule ProgID: HS_S3DRules.PipeAttByPipeSize |
IJUAhs_InsulationDef:: |
Currently not available. |
|
IJUAhs_InsulationSel:: |
Specifies the attribute that is used to select the InsulationPart. The InsulationPart is used by default if you do not specify any value. |
hsSelection: 1 - By Rule 2 - By Input |
IJUAhs_Insulation2:: |
Specifies the second insulation part number or part class to use for the support. |
Specify the part number. Alternatively, specify the part class. |
IJUAhs_Insulation2Rl:: |
Specifies a hgrSupportRule that returns an insulation part number. The hanger rule must be the name of an existing rule in the catalog. |
Examples: Rule Name: PipeAttByPipeSize Rule ProgID: HS_S3DRules.PipeAttByPipeSize |
IJUAhs_Insulation2Def:: |
Currently not available. |
|
IJUAhs_Insulation2Sel:: |
Specifies the attribute that is used to select the Insulation2Part. The Insulation2Part is used by default if you do not specify any value. |
hsSelection: 1 - By Rule 2 - By Input |