A Trunnion support uses all the General Attributes specified in the Common Attributes section and the following attributes:
Attribute Name |
Description |
Implementation Details |
---|---|---|
IJUAhsTrunnType:: |
Specifies the codelist value that determines if the Trunnion is a single or a Double Trunnion. You can use a Double Trunnion on a straight pipe only and a Single Trunnion on a straight pipe or on elbows. |
1 - Single 2 - Double |
IJUAhsCapConfig:: |
Specifies a codelist value that determines how a cap plate is connected to the end of the Trunnion Pipe. |
1 - External 2 - Internal |
IJUAhsHorzPipeConn:: |
Specifies a codelist value that determines the point at which the Trunnion connects with the supporting structure when the Trunnion is placed on a pipe. This attribute is used only when the Trunnion is supporting a pipe or an elbow that is parallel to the supporting structure. |
1 - Center 2 - Toward 3 - Away |
IJUAhsElbowConn:: |
Specifies a codelist value that determines the point at which the trunnion connects with the supported elbow. This attribute is used only when the Trunnion supports a pipe elbow. |
1 - Center - Trunnion is lined up with the center of the horizontal pipe. 2 - Inside - Top or bottom of the trunnion os lined up with the horizontal pipe on the inside of the elbow curve. 3 - Outside - Bottom or top of the trunnion is lined up with the horizontal pipe on the outside of the elbow curve. 4 - Top - Top of the trunnion is lined up with the bottom of the horizontal pipe, irrespective of the direction of the elbow curve. 5 - Bottom - Bottom of the trunnion is lined up with the bottom of the horizontal pipe, irrespective of the direction of the elbow curve. |
IJUAhsElbowConnOffVal::ElbowConnectionOffVal |
Specifies the offset distance from Pipe center. |
|
IJUAhsElbowConnOffValRl::ElbowConnectionOffValRl |
Specifies a rule to get the ‘ElbowConnectionOffVal’ value. |
If you specify a value, the software gets the ‘ElbowConnectionOffVal’ using rule. |