The Stiffener assembly uses the following attributes:
Name |
User Name |
Category |
On Property Page |
Read Only |
---|---|---|---|---|
AutoDim |
Auto Dimension |
Dimensions |
Yes |
Yes |
OffsetFromPipeCenter |
Offset From Pipe Center |
Dimensions |
Yes |
No |
Attribute Name |
Description |
Implementation Details |
---|---|---|
IJUAhsStiffenerAutoDim:: |
Determines whether the plate dimension must be set based on the connecting steel (On) or on the part (Off). |
Use the following values: 0 (Off) - Uses the part defined values. 1 (On) - Uses the dimensions from the structure that the support connects to. |
IJUAhsStiffenerOffset:: |
Specifies the offset along the structure that the structure connects. The offset is based on the location of the pipe.
|
|
IJUAhsStiffNum::NumOfStiff |
Specifies the number of stiffeners that are to be placed. You can place a maximum of 2 stiffeners. |
|
IJUAhsStiffNumRL:: |
Specifies the rule that determines the number of stiffeners to be placed with the support. |
|
IJUAhsStiffenerLen::StiffenerLength |
Specifies the length of the stiffener. |
|
IJUAhsStiffenerLenRl::StiffenerLengthRule |
Specifies a rule that gives the stiffener length. |
|
IJUAhsStiffenerWid::StiffenerWidth |
Specifies the width of the stiffener. |
|
IJUAhsStiffenerWidRl::StiffenerWidthRule |
Specifies a rule that gives the stiffener width. |
|
IJUAhsStiffenerVerOffset::StiffenerVerOffset |
Specifies the offset distance to move stiffener vertically. |
|
IJUAhsStiffenerVerOffsetRl::StiffenerVerOffsetRl |
Specifies a rule that gives the stiffener vertical offset. |
|
IJUAhsStiffenerOffset::StiffenerOffset |
Specifies the stiffener offset. |