The following table lists part attributes for a Limit Stop support:

Name

User Name

OA

Category

On Property Page

Read Only

StopPart

Stop

No

Standard

No

No

StopRule

Stop – Rule

No

Standard

No

No

StopSide

Stop – Side

No

Dimensions

Yes

No

StopClearance

Stop – Clearance

Yes

Dimensions

Yes

No

Attribute Name

Description

Implementation Details

IJUAhs_Stop::StopPart

Specifies the Limit Stop part number or the part class to use for the support.

Use the following part class ProgID types:

1- RichHgrBeam

2 - TwoStandardPort

3 - Guide

IJUAhs_StopSide::StopSide

Specifies a codelist value that decides where to place the Limit Stop.

hsSupSide:

1 - One side

2 - Both sides

IJUAhs_StopToggle::
StopToggle

Specifies the codelist value to toggle the side on which the Limit Stop is placed.

  • The StopToggle value is ignored if the Limit Stop is placed on both the sides.

  • To set the correct orientation, adjust Angle1 when you toggle.

hsStopSideToggle:

1 - Side 1

Illustration of Limit Stop Attribute - IJUAhs_StopToggle - Side 1

2 - Side 2

Illustration of Limit Stop Attribute - IJUAhs_StopToggle - Side 2

IJUAhs_StopClearance::
StopClearance

Specifies the space between the edge of the supporting steel and the Limit Stop.

The StopClearance value depends on the Structure Connection.

If Stop Clearance is equal to 0, the Limit Stops are placed against the supporting steel or against each other. A positive value for the Stop Clearance increases the space between the Limit Stops.

If Structure Connection is equal to 1, clearance is calculated as the space between the edge of the supporting steel and Limit Stop.

If Structure Connection is equal to 2, clearance is measured using a starting point as 0.

Use the following definitions:

1 - Structure Connection

Illustration of Limit Stop Attribute - IJUAhs_StopClearance - Structure Connection 1

2 - Structure Connection

Illustration of Limit Stop Attribute - IJUAhs_StopClearance - Structure Connection 2

For more information on how to use part attributes and dimensional attributes, see Part Specifications and Input Values.