General Attributes - Intergraph Smart Reference Data Standard Database - Version 12.2 - Help - Hexagon PPM

Standard Database for Intergraph Smart Reference Data Hangers and Supports Help

Language
English
Product
Intergraph Smart Reference Data Standard Database
Search by Category
Help
Standard Database for Smart Reference Data Version
12.2

A Pipe to Pipe support uses all the General Attributes specified in the Common Attributes section and the following other general attributes:

Name

User Name

Category

On Property Page

Read Only

SupportNumber

Support Number

Standard

Yes

Yes

FrameOrientation

Frame Orientation

Standard

Yes

No

PipeConfiguration

Pipe Configuration

Standard

Yes

No

MaxPipeQuantity

Max Pipe Quantity

Standard

Yes

No

Attribute Name

Description

Implementation Details

IJUAhsFrameOrientation::
FrameOrientation

Specifies a codelist value that determines the orientation of the support with respect to the supporting object or the global coordinate system.

IJUAhsPipeConfiguration::
PipeConfiguration

Specifies whether the support is placed on the parallel pipes or the perpendicular pipes.

The following values are accepted:

Parallel

Perpendicular

IJUAhsMaxPipeQty::
MaxPipeQuantity

Specifies the maximum number of pipes that can be used with the support.

The application displays an error if the number of pipes selected is more than the MaxPipeQuantity.