The Repad support assembly uses the following input dimensions

Attribute Name

Description

Implementation Details

IJUAhs_RepadLength::
RepadLength

Specifies the Repad length

The following definition is supported:

  1. Direct - Specifies direct measurement

IJUAhs_RepadThk::
RepadThk

Specifies Repad thickness.

The following definition is supported:

  1. Direct - Specifies direct measurement

IJUAhs_RepadAngle::
RepadAngle

Specifies the angle at which the Repad is placed on the pipe.

The following definitions are supported:

  1. Clockwise - The angle is measured by moving the Repad in clockwise direction starting with 0, being the bottom of the pipe.

  2. Anticlockwise - The angle is measured by moving the Repad in counterclockwise direction starting with 0. 0implies bottom of the pipe.

IJUAHS_RepadAngleDim::
AngleDim

Specifies the sweep angle of the repad shape.

The following definition is supported:

  1. Pipe Center to Bottom

Repad - Dimension Attributes - Sweep Angle