Sets the amount of extra pipe that is added for shop test purposes where certain welds are cut-off together with a short length of pipe after testing.
Type 0 to obtain zero allowance, or type a value (in the range 0-999) of an alternative allowance.
Defines:
Option Switch - 22, Pos 7-9
I-Configure - CutList.ShopWeldAllowance
Shop Test Allowance is applied only to shop test welds.