Controls how Isogen interprets and acts up small dimensional deviations detected in the input data file.
Dimensional deviations can lead to small, unwanted skews being generated on the isometric drawing. You can use Difference Limit to define a dimensional cut-off value, whereby Isogen ignores any offset coordinate numerically below this value.
Set to the required dimensional tolerance in millimeters or inches. For example, you can type 1.0 mm or 0.04 inch. When set to 0, no dimensional offset tolerance is set.
Defines:
Option Switch - 116, Pos 1-3
I-Configure - Drawing.Dimensions.MinOffset