Controls the type of material list that Isogen outputs on the isometric drawing.

  • Normal creates a special type of material list.

  • Special gives every item a separate entry except gaskets and bolts, which are accumulated. Give pulled bends a U prefix and welds a W or B prefix.

  • Normal with alpha pointers suppresses creation of a special type of material list. The software uses an alpha system of material list pointers (A, B, C.) instead of the default numeric system.

Defines:

Option Switch - 23, Pos 2
I-Configure - MaterialList.VariableLayout.MLType