Component Count - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls the dimensioning of branches based on the number of components. Gasket and bolt entries are counted as components.

Type a value in the range 0-99. Branches that contain a number of components less than or equal to the specified value are not dimensioned. The branch in the example has six components: a weldolet, a weld-neck flange, two gaskets, a valve, and a blind flange. Setting Component Count to 6 or higher results in the branch not being dimensioned.

  • To dimension all branches, type 0.

  • Isogen does not suppress dimensions for any branch that contains pipe or pipe block.

  • Isogen treats fixed length pipe as a component. As such, branch dimensions are suppressed.

  • You cannot use Component Count to suppress dimensions for tapped branches.

  • Component Count can work independently of or in conjunction with Nominal Size, depending upon your requirements.

Defines:

Option Switch - 81, Pos 7-8
I-Configure - Drawing.Dimensions.BranchCPTLimit