Group graphics by UCI - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls how components are grouped in the output CAD file.

When you select this option, graphics are grouped based on the Unique Component Identifier (UCI). For example, if you output a pipeline in which an olet/support has been placed in the middle of a pipe, the resulting isometric drawing splits that pipe into two segments on each side of the component. In this instance, you can use Option Switch 98 to keep the entire pipe together in the drawing.

Typically, the 3D system that generates the drawing data supplies this UCI. Selecting this option makes it easier to correlate the 2D isometric drawing with the 3D data when both are published to SmatPlant Foundation.

Defines:

Option Switch - 98, Pos 1
I-Configure - Drawings.Controls.GroupGraphicsbyUCI