Drawing Splitting ( % ) - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls the amount of drawing data that triggers a drawing split.

Specify a value in the range 90-110. The specified setting is a scale factor expressed as a percentage. Setting a value less than 100 causes less of the pipeline to appear on each drawing before automatic splitting occurs, resulting in a less crowded drawing. If a particular value does not work, gradually adjust the value and re-extract the drawing to check the results.

Defines:

Option Switch - 38
I-Configure - Drawing.Controls.PipelineSplitting

This property is intended only for modest modifications of the drawing whitespace.