Where applicable, each AText description includes its respective default value. If a default value is not specified, the AText is normally left blank.

For each AText, three options are available:

  • <Default> uses the default AText value.

  • <Suppress> suppresses the AText value.

  • <Edit value> modifies the AText value with the user-specified entry.

Flat Spool Offset Callout

Shows the offset on flat spools. The default value is OFFSET DIRECTION.

AText ID:

-435

? Value:

None

$ Supported:

No

ATexts -481 to -486 are used in DIRECTION records in the pipeline input data file when indicating compound directions for some components in skewed pipelines. They are also used when Isogen is generating ORIENTATION and CONNECTION DIRECTION messages on flat spools.

X Direction

Shows the direction component in positive X. The default value is E.

AText ID:

-481

? Value:

None

$ Supported:

No

Y Direction

Shows the direction component in positive Y. The default value is N.

AText ID:

-482

? Value:

None

$ Supported:

No

-X Direction

Shows the direction component in negative X. The default value is W.

AText ID:

-483

? Value:

None

$ Supported:

No

-Y Direction

Shows the direction component in negative Y. The default value is S.

AText ID:

-484

? Value:

None

$ Supported:

No

Z Direction

Shows the direction component in positive Z. The default value is U.

AText ID:

-485

? Value:

None

$ Supported:

No

-Z Direction

Shows the direction component in negative Z. The default ix D.

AText ID:

-486

? Value:

None

$ Supported:

No

Flat Spool Flat Direction

Points to 2D and 3D skew enclosure triangles at eccentric reducers to indicate a flat direction on flat spools. The default value is FLAT DIRECTION.

AText ID:

-492

? Value:

None

$ Supported:

No

Flat Spool Spindle Direction

Points to 2D and 3D skew enclosure triangles located at spindles on flat spools. The default value is SPINDLE DIRECTION.

AText ID:

-493

? Value:

None

$ Supported:

No

Flat Spool Support Direction

Points to 2D and 3D skew enclosure triangles located at supports on flat spools. The default value is SUPPORT DIRECTION.

AText ID:

-494

? Value:

None

$ Supported:

No

Flat Spool Branch Direction

Points to 2D and 3D skew enclosure triangles located at undeveloped set-on branches or single olets on flat spools. The default value is BRANCH DIRECTION.

AText ID:

-495

? Value:

None

$ Supported:

No

Flat Spool Window Direction

Points to 2D and 3D skew enclosure triangles located at sight glasses on flat spools. The default value is WINDOW LOCATION.

AText ID:

-496

? Value:

None

$ Supported:

No