Treat IDFGEN Soft Disconnect as Error - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls how the software reports a soft disconnection that it finds during isometric extraction.

When you select the check box, the drawing is not produced if the software encounters a Soft disconnect error (code 2024) during the extraction process. An error message is also written to the Smart 3D drawing log.

If you do not select Treat IDFGEN Soft Disconnect As Error, the software writes a message to the log file but produces the drawing as usual despite the disconnected pipeline. This is the default behavior.

Defines:

Option Switch - N/A
I-Configure - S3D.Drawing.Controls.TreatIDFGEN2024AsError

  • The software uses the standard error icon to indicate the drawing failure.

  • Error 2024 occurs when IDFGEN encounters gaps greater than the specified tolerance (but less than 8mm) during isometric extraction.