When installing Smart Engineering Manager in command line when its configured to run on Oracle Server, add the following:
Parameter |
Default Value |
Mandatory |
Notes |
---|---|---|---|
SiteIniPath |
Yes |
Default value – as in the site |
|
PackageFile |
The name of the datanase that Smart Engineering Manager is connected to |
Yes |
Default value – plant name |
PlantName |
true |
optional |
|
PlantDescription |
true |
optional |
|
PlantPath |
<plant backup folder>CopyOf<plant name>.zip |
optional |
|
PlantBackupPath |
path to the shared storage folder for backing up the plant files |
optional |
|
SeedLocationPath |
optional |
||
SaveSeedLocation |
false |
optional |
|
SystemUser |
true |
||
SystemPassword |
true |
optional |
Parameters and Values on Oracle platform
Parameter |
Default Value |
Notes |
---|---|---|
OracleAlias |
default value – as in the site |
|
SchemaPlantTableSpace |
default value – users |
|
SchemaPlantTempTableSpace |
default value – temp |
|
SchemaDdPlantTableSpace |
default value – users |
|
SchemaDdPlantTempTableSpace |
default value – temp |
|
isChangeGuid |
default value – true |
|
SchemaPlantUser |
default value – plant name |
|
SchemaPlantPassword |
default value – plant nam) |
|
SchemaDdPlantUser |
default value – plant name +"d" |
|
SchemaDdPlantPassword |
default value – plant name+"d" |
General parameters and values if the package includes P&ID
Parameter |
Default Value |
Notes |
---|---|---|
Pid |
(default value – true) |
|
SchemaPidUser |
(default value – plant name+"pid") |
|
SchemaPidPassword |
(default value – plant name+"pid") |
|
SchemaDdPidUser |
(default value – plant name+"pidd") |
|
SchemaDdPidPassword |
(default value – plant name+"pidd") |
|
RefPidDataPath |
(default value – plant path + \ RefPid) |
Parameters if the package includes P&ID and its on an Oracle platform
Parameter |
Default Value |
Notes |
---|---|---|
SchemaPidTableSpace |
(default value – users) |
|
SchemaPidTempTableSpace |
(default value – temp) |
|
SchemaDdPidTableSpace |
(default value – temp) |
|
SchemaDdPidTempTableSpace |
(default value – temp) |
General parameters If the package includes Smart Electrical
Parameter |
Default Value |
Notes |
---|---|---|
Sel |
default value – true |
|
SchemaSelUser |
default value – plant name+"el" |
|
SchemaSelPassword |
default value – plant name+"el" |
|
SchemaDdSelUser |
default value – plant name+"eld" |
|
SchemaDdSelPassword |
default value – plant name+"eld" |
|
SchemaRefSelUser |
default value – plant name+"el" |
|
SchemaRefSelPassword |
default value – plant name+"elref" |
|
RefSelDataPath |
default value – plant path + \ RefEl |
Parameters if the package includes Smart Electrical and its on an Oracle platform
Parameter |
Default Value |
Notes |
---|---|---|
SchemaSelTableSpace |
default value – users |
|
SSchemaSelTempTableSpace |
default value – temp |
|
SchemaDdSelTableSpace |
default value – users |
|
SchemaDdSelTempTableSpace |
default value – temp |
|
SchemaRefSelTableSpace |
default value – users |
|
SchemaRefSelTempTableSpace |
default value – temp |