Displays properties for duct split features. A split feature represents a break and a joint in the duct. It divides a duct along a straight section into two straight features to connect the ends of the two ducts at the cut location. Examples are a joint sleeve, butt weld, coupling, and a flange set, either sloped or flat. These examples also are called split parts, which the software reads from the reference data.
The order in which the properties display in your view depends on your configuration.
Approval State
Specifies the status of the selected object or filter. Changing this property sets the Status. The display depends on your access level. You might be unable to change the status of the object. The list is defined by the ApprovalStatus codelist.
Smart 3Dx saves an object to the database when you change that object's status. Use Undo (CTRL + Z) to reverse the status change.
You can only edit or manipulate an object with a status of Working.
Corner Radius
Specifies the radius of the cross-section and is available for the Rectangle shape.
Created by
Specifies the name of the person who created the object.
Cross Section Shape
Specifies the shape of the object cross section.
Date Created
Specifies the creation date of the object.
Date Last Modified
Specifies the date of the last modification to the object.
Depth Slope
Specifies the slope angle to the depth axis. Depth Slope is displayed only if you select a reference data type that supports slope. Values range from -89 to 89.
Dimension Base Outer
Specifies the outer dimension of the base of the nozzle.
Hyperlink
Specifies the URL or local file path associated with the object. Click the hyperlink to open the page or object in your default browser. Point to the hyperlink to display the URL or path as a tooltip.
Description
Specifies the descriptive text associated with the hyperlink.
URL
Specifies the web address or local file name associated with the hyperlink. The URL must include the protocol, such as http: or https:, as well as the domain name. For example, https://hexagonppm.com/.
Insulation Material
Specifies the material of the insulation.
Piping
If you selected Not Insulated in the Insulation Specification box, you cannot change the value in the Insulation Material box. However, if you manually entered the insulation specification, you must provide a corresponding insulation material as per the specification. If you selected an insulation specification from the available list, the software automatically displays the corresponding material as per the specification.
HVAC
If you select Not Insulated, you cannot change the information in Insulation Thickness.
Select More to select an insulation material from the Catalog. To change the options on the list, edit the Insulation Material select list in Catalog. See Select Insulation Material Dialog.
Insulation Purpose
Specifies the purpose of the insulation. If you selected Not Insulated in the Insulation Specification box, you cannot change the information in the Insulation Purpose box. However, if Insulation Specification is manually defined, you can select the purpose of the insulation in this box. If Insulation Specification is a selected reference data insulation specification, the software reads the purpose from the insulation specification from the reference data and displays it here.
To change the options on the list, edit the Insulation Purpose select list in Catalog.
Insulation Temperature
Specifies the temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example) when specifying this value.
Insulation Thickness
Specifies the thickness of the insulation.
Piping
If you selected Not Insulated in the Insulation Specification box, you cannot change the value in the Insulation Thickness box. However, if you manually entered the insulation specification, you must provide a corresponding insulation thickness value as per the specification. If you selected an insulation specification from the available list, the software automatically displays the corresponding thickness value as per the specification.
HVAC
If you selected Not Insulated in the Insulation Material box, this property is unavailable.
Last Modified by
Specifies the name of the person who last modified the object.
Part Type
Specifies the part type of the manufacturing object.
Shape Depth
Specifies the depth of the nozzle shape.
Shape Width
Specifies the width of the nozzle shape.
Tightness
Specifies the water tightness of the object. This value is inherited from the parent system.
Wall Thickness
Specifies the thickness of the object.
Width Slope
Specifies the slope angle to the width axis. Width Slope is displayed only if you select a reference data type that supports slope. Values range from -89 to 89.