Pipe Turn Feature Properties - Intergraph Smart 3D - Help - Hexagon PPM

Intergraph Smart 3Dx Property Descriptions

Language
English
Product
Intergraph Smart 3D
Subproduct
3Dx
Search by Category
Help
Smart 3D Version
13.1

Displays properties for pipe turn features. A pipe turn feature is the high-level design object for elbows.

The order in which the properties display in your view depends on your configuration.

Approval State

Specifies the time or date the status of the piping materials class was approved.

Area

Specifies the cross-section area for the object. This property is read-only. To change this value, edit the object properties in Catalog or in the corresponding workbook.

Auxiliary Treatment Requirement

Specifies the auxiliary treatment requirement. To change the options on the list, edit the Auxiliary Treatment select list in Catalog.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

Auxiliary Treatment Type

Specifies the auxiliary treatment type for the object. To change the options on the list, edit the Auxiliary Treatment select list in Catalog.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.

Bend Angle

Specifies the required angle for an object.

Bend Radius Multiplier

Specifies the turn radius that the software will use for turns while routing as a multiplier function of the duct dimension in the plane of the turn. The dimension used is the diameter for round cross section, the width dimension, or the depth dimension, depending upon the plane of the turn. If you change the bend radius multiplier, the software automatically changes the throat radius value.

The list displays the last five values in numeric order. If this is the first time in the session file, the Bend Radius Multiplier is the default from the active specification.

Cleaning Requirement

Specifies the cleaning requirement for the object. To change the options on the list, edit the Cleaning Requirement select list in Catalog.

Coating Color

Specifies the color of the object coating. To change the options on the list, edit the Coating Color select list in Catalog. Smart 3Dx includes this property in the painting area report.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.

Commodity Option

Specifies short code for the primary commodity object from the Piping job specification.

Correlation Approval Status

Specifies whether the object is approved with discrepancies in the three-dimensional data compared with design basis data. The list is defined by the EFWCorrelationApprovalStatus sheet in the AllCodelist workbook.

Topology mismatch approved

Indicates that the object topology mismatch can be ignored.

Data and Topology mismatches approved

Indicates that the object data and topology mismatches can be ignored.

None

Indicates that you do not approve a mismatch.

Correlation Basis

Specifies whether the object is correlated to a P&ID object. The list is defined by the EFWCorrelationBasis select list.

Correlate Object

Indicates that the object has a correlating object in a P&ID.

No correlation is required

Indicates that the object does not have a correlating object in a P&ID.

Correlation Status

Specifies whether the object has been correlated to an object in a P&ID. The list is defined by the EFWCorrelationStatus select list.

Created by

Specifies the name of the person who created the object.

Date Created

Specifies the creation date of the object.

Date Last Modified

Specifies the date of the last modification to the object.

Exterior Coating Area

Specifies the area of the coating for the object.

Exterior Coating Requirement

Specifies the coating requirement for the object. To change the options on the list, edit the Coating Type select list in Catalog.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

Exterior Coating Type

Specifies the type of coating for the object. To change the options on the list, edit the Exterior Coating Type select list in Catalog.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.

Exterior Surface Treatment Requirement

Specifies the exterior treatment requirement for the object. To change the options on the list, edit the Exterior Surface Treatment select list in Catalog.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

Exterior Surface Treatment Type

Specifies the exterior treatment type for the object. To change the options on the list, edit the Exterior Surface Treatment select list in Catalog.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.

Heat Tracing Requirement

Specifies whether the object is heat-traced. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

Heat Tracing Type

Specifies the type of heat-tracing. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.

Heat Tracing Medium

Specifies the heat-tracing medium to apply to the object. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.

Heat Tracing Medium Temperature

Specifies the temperature of the heat-tracing medium. Include the unit of measurement of temperature (K for Kelvin, F for Fahrenheit, or C for Celsius, for example).

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.

Hyperlink

Specifies the URL or local file path associated with the object. Click the hyperlink to open the page or object in your default browser. Point to the hyperlink to display the URL or path as a tooltip.

Description

Specifies the descriptive text associated with the hyperlink.

URL

Specifies the web address or local file name associated with the hyperlink. The URL must include the protocol, such as http: or https:, as well as the domain name. For example, https://hexagonppm.com/.

Insulation Material

Specifies the material of the insulation.

Piping

The software displays this property only when the Insulation Type is Specification Driven or User Defined.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value. This option displays when the Insulation Type is Specification Driven.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven . This option displays when the Insulation Type is User Defined.

User Driven

Allows you to select a value. Click to switch to Rule Driven .

This option displays when the Insulation Type is User Defined.

The User Driven option is not active if it is not present on the parent pipe run.

HVAC

If you select Not Insulated, you cannot change the information in Insulation Thickness.

Select More to select an insulation material from the Catalog. To change the options on the list, edit the Insulation Material select list in Catalog. See Select Insulation Material Dialog.

Insulation Purpose

Specifies the purpose of insulation. The software displays this property only when the Insulation Type is Specification Driven or User Defined. To change the options on the list, edit the Insulation Purpose select list in Catalog.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value. This option displays when the Insulation Type is Specification Driven.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven . This option displays when the Insulation Type is User Defined.

User Driven

Allows you to select a value. Click to switch to Rule Driven .

This option displays when the Insulation Type is User Defined.

The User Driven option is not active if it is not present on the parent pipe run.

Insulation Specification

Specifies the insulation specification for the object. The software displays this property only when the Insulation Type is Specification Driven.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

The User Driven option is not active if it is not present on the parent pipe run.

Insulation Temperature

Specifies the temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example) when specifying this value.Specifies the temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example) when specifying this value. The software displays this property only when the Insulation Type is User Defined or Specification Driven.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

The User Driven option is not active if it is not present on the parent pipe run.

Insulation Thickness

Specifies the thickness of the insulation.

Piping

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value. This option displays when the Insulation Type is Specification Driven.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven . This option displays when the Insulation Type is User Defined.

User Driven

Allows you to select a value. Click to switch to Rule Driven .

This option displays when the Insulation Type is User Defined.

The User Driven is not active if:

  • It is not present on the parent pipe run.

  • The Insulation Material on pipe feature does not support the value of the Insulation Thickness on pipe run.

HVAC

If you selected Not Insulated in the Insulation Material box, this property is unavailable.

Insulation Type

Specifies the type of the insulation.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

Interior Coating Area

Specifies the area of the interior coating for the object.

Interior Coating Requirement

Specifies the interior coating requirement for the object. To change the options on the list, edit the Coating Type sheet in the AllCodeLists.xls workbook in the reference data.

Interior Surface Treatment Requirement

Specifies the interior treatment requirement for the object. To change the options on the list, edit the Interior Surface Treatment select list in Catalog.

Last Modified by

Specifies the name of the person who last modified the object.

Length

Specifies the object length.

Nominal Diameter

Specifies the nominal piping diameter for the object. This property is inherited from the parent pipe run. The list is populated based on the Specification selected.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

Outer Diameter

Specifies the outer diameter of the object.

Specification

Specifies the specification of the object. This property is inherited from the parent pipe run.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

Steamout Pressure

Specifies the steamout pressure for the object. Include the pressure unit of measure (psi for pounds per square inch for example).

Steamout Requirement

Specifies the steamout requirement for the object. To change the options on the list, edit the Steamout Requirement select list in Catalog.

Steamout Temperature

Specifies the steamout temperature for the object. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example).

Tag

Specifies a tag that identifies the object.

Throat Radius

Specifies the throat radius of the turn transition. The list displays the last ten radii that you entered.

Type

Specifies the path feature type.