Displays properties for conduit runs. A conduit run is a connected series of features that usually have the same specification. A conduit run includes straight features; along-leg features such as branches, transitions, and reducers; turn features; and end features.
The order in which the properties display in your view depends on your configuration.
Approval State
Specifies the status of the selected object or filter. Changing this property sets the Status. The display depends on your access level. You might be unable to change the status of the object. The list is defined by the ApprovalStatus codelist.
Smart 3Dx saves an object to the database when you change that object's status. Use Undo (CTRL + Z) to reverse the status change.
You can only edit or manipulate an object with a status of Working.
Auxiliary Treatment Requirement
Specifies the auxiliary treatment requirement. To change the options on the list, edit the Auxiliary Treatment select list in Catalog.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
Cleaning Requirement
Specifies the cleaning requirement for the object. To change the options on the list, edit the Cleaning Requirement select list in Catalog.
Cleaning Responsibility
Specifies the party responsible for cleaning the object. To change the options on the list, edit the Cleaning Responsibility select list in Catalog.
Coating Color
Specifies the color of the object coating. To change the options on the list, edit the Coating Color select list in Catalog. Smart 3Dx includes this property in the painting area report.
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.Created by
Specifies the name of the person who created the object.
Date Created
Specifies the creation date of the object.
Date Last Modified
Specifies the date of the last modification to the object.
Design Responsibility
Specifies the party responsible for designing the object. To change the options on the list, edit the Design Responsibility select list in Catalog.
Exterior Coating Area
Specifies the area of the coating for the object.
Exterior Coating Requirement
Specifies the coating requirement for the object. To change the options on the list, edit the Coating Type select list in Catalog.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
Exterior Surface Treatment Requirement
Specifies the exterior treatment requirement for the object. To change the options on the list, edit the Exterior Surface Treatment select list in Catalog.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
Fabrication Responsibility
Specifies the party responsible for fabricating the object. To change the options on the list, edit the Fabrication Responsibility select list in Catalog.
Fill Efficiency
Specifies the efficiency of the stacking of cables in the cableway. Type a real number, integer, or percent. For example, type 0.9, 90, or 90%.
Hyperlink
Specifies the URL or local file path associated with the object. Click the hyperlink to open the page or object in your default browser. Point to the hyperlink to display the URL or path as a tooltip.
Description
Specifies the descriptive text associated with the hyperlink.
URL
Specifies the web address or local file name associated with the hyperlink. The URL must include the protocol, such as http: or https:, as well as the domain name. For example, https://hexagonppm.com/.
Installation Responsibility
Specifies the party responsible for installing the object. To change the options on the list, edit the Installation Responsibility select list in Catalog.
Interior Coating Area
Specifies the area of the interior coating for the object.
Interior Coating Requirement
Specifies the interior coating requirement for the object. To change the options on the list, edit the Coating Type sheet in the AllCodeLists.xls workbook in the reference data.
Interior Surface Treatment Requirement
Specifies the interior treatment requirement for the object. To change the options on the list, edit the Interior Surface Treatment select list in Catalog.
Last Modified by
Specifies the name of the person who last modified the object.
Name
Specifies the name of the selected object. If the name is too long to entirely display in the box, point to the box to display the complete name as a tool tip. If the name is not defined by a rule, User Defined displays. If this name is generated by a naming rule, Naming Rule displays. If you type a name in this box, Smart 3Dx automatically changes the naming rule to User Defined.
NCD Unit Type
Specifies the units for the NCD value. Select mm or in from the list.
Nominal Conduit Diameter
Specifies the nominal diameter (NCD) of the straight feature. If displays in the box, the NCD for the straight feature is inherited from the conduit run to which the straight feature belongs. If the icon does not display, and you want to use the conduit specification from the conduit run, select Use Run NCD. If you have manually selected the part, the NCD of the selected part displays and you cannot change it.
Painting Responsibility
Specifies the party responsible for painting the object. To change the options on the list, edit the Painting Responsibility select list in Catalog.
Parent System
Specifies the parent system for the object. Recently used systems that are appropriate to assign as the parent system for this object display in the list along with the Select from Workspace and Select from Model options. The most recently used system displays at the top.
The parent system of the object must have an Approval Status of Working before you can change the Parent System value. If the Approval Status of the parent system is not set to Working, this value is read-only.
Select Interactively
Turns on or off the interactive selection. When this option is on, you can select the parent object in a graphic view or any of the explorers.
Select from Workspace
Displays the Select Parent System Dialog with the Workspace tab open. The workspace is the subset of the active model database you specified when you started your design session. Navigate the hierarchy to select the parent system, and then click OK.
Select from Model
Displays the Select Parent System Dialog with the Model tab open. The model is all of the objects in the active model database, including those that are not part of your workspace. Navigate the hierarchy to select the parent system, and then click OK.
Requisition Responsibility
Specifies the party responsible for ordering the object. To change the options on the list, edit the Requisition Responsibility select list in Catalog.
Signal Type 1
Specifies the signal that passes through the cable, which Smart 3Dx uses in tray fill calculations. To change the options on the list, edit the Signal Type select list in Catalog.
Signal Type 2
Specifies the signal that passes through the cable, which Smart 3Dx uses in tray fill calculations. To change the options on the list, edit the Signal Type select list in Catalog.
Signal Type 3
Specifies the signal that passes through the cable, which Smart 3Dx uses in tray fill calculations. To change the options on the list, edit the Signal Type select list in Catalog.
Signal Type 4
Specifies the signal that passes through the cable, which Smart 3Dx uses in tray fill calculations. To change the options on the list, edit the Signal Type select list in Catalog.
Signal Type 5
Specifies the signal that passes through the cable, which Smart 3Dx uses in tray fill calculations. To change the options on the list, edit the Signal Type select list in Catalog.
Steamout Pressure
Specifies the steamout pressure for the object. Include the pressure unit of measure (psi for pounds per square inch for example).
Steamout Requirement
Specifies the steamout requirement for the object. To change the options on the list, edit the Steamout Requirement select list in Catalog.
Steamout Temperature
Specifies the steamout temperature for the object. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example).
Supply Responsibility
Specifies the party responsible for delivering the object. To change the options on the list, edit the Supply Responsibility select list in Catalog.
Testing Responsibility
Specifies the party responsible for testing on the object. To change the options on the list, edit the Testing Responsibility select list in Catalog.
Voltage Grade