The following table contains the pipeline attributes and calculated values that you can define for the Material Control report title block. Information about including a title block in the report is available in Report Definition options.
Strings enclosed in single quotes (') in the PCF and IDF columns are equivalent. For example, 'AREA' produces the same ouput as '-10' in the report title block: the value of the pipeline attribute AREA.
Pipeline Attribute |
PCF |
IDF |
AREA |
'AREA' |
'-10' |
NUMBER-OF-DRAWINGS |
'NUMBER-OF-DRAWINGS' |
'-703' |
PIPELINE-REFERENCE |
'PIPELINE-REFERENCE' |
'-6' |
REVISION |
'REVISION' |
'-8' |
PROJECT-IDENTIFIER |
'PROJECT-IDENTIFIER' |
'-9' |
BATCH |
'BATCH' |
'-10' |
PIPING-SPEC |
'PIPING-SPEC' |
'-11 |
NOMINAL-CLASS |
'NOMINAL-CLASS' |
'-12' |
NOMINAL-RATING |
'NOMINAL-RATING' |
'-12' |
DATE-DMY |
'DATE-DMY' |
'-14' |
INSULATION-SPEC |
'INSULATION-SPEC' |
'-15' |
TRACING-SPEC |
'TRACING-SPEC' |
'-16' |
PAINTING-SPEC |
'PAINTING-SPEC' |
'-17' |
PIPELINE-TEMP |
'PIPELINE-TEMP' |
'-18' |
SURFACE-AREA |
'SURFACE-AREA' |
'-738' |
MAXIMUM-N.S. |
'MAXIMUM-N.S. |
|
SYSTEM-REFERENCE |
'SYSTEM-REFERENCE' |
'-25' |
NUMBER-OF-SPOOLS |
'NUMBER-OF-SPOOLS' |
'-763' |
EQUIPMENT-TRIM- |
'EQUIPMENT-TRIM- |
'-29' |
WELD-DIAMETERS |
'WELD-DIAMETERS' |
'-731' |
WELD-DIAMETERS- |
'WELD-DIAMETERS- |
'-759' |
WELD-DIAMETERS- |
'WELD-DIAMETERS- |
'-760' |
WELD-DIAMETERS- |
'WELD-DIAMETERS- |
'-761' |
WELD-DIAMETERS-PIPE |
'WELD-DIAMETERS-PIPE |
'-776' |
WELD-DIAMETERS- |
'WELD-DIAMETERS- |
'-777' |
MISC-SPEC1 |
'MISC-SPEC1' |
'-41' |
MISC-SPEC2 |
'MISC-SPEC2' |
'-42' |
MISC-SPEC3 |
'MISC-SPEC3' |
'-43' |
MISC-SPEC4 |
'MISC-SPEC4' |
'-44' |
MISC-SPEC5 |
'MISC-SPEC5' |
'-45' |
CLEANING-REQUIREMENT |
'CLEANING-REQUIREMENT' |
'-1100' |
PAINT-COLOUR |
'PAINT-COLOUR' |
'-1101' |
CONSTRUCTION-TYPE |
'CONSTRUCTION-TYPE' |
'-1102' |
DESIGN-PACKAGE |
'DESIGN-PACKAGE' |
'-1103' |
DESIGN-TEMPERATURE |
'DESIGN-TEMPERATURE' |
'-1104' |
ENGINEERING-WORK- |
'ENGINEERING-WORK- |
'-1105' |
INSTALLATION-WORK- |
'INSTALLATION-WORK- |
'-1106' |
FLUID-CODE |
'FLUID-CODE' |
'-1107' |
HANDOVER-SYSTEM-ID |
'HANDOVER-SYSTEM-ID' |
'-1108' |
TRACING-REQUIREMENT |
'TRACING-REQUIREMENT' |
'-1109' |
TEST-PRESSURE |
'TEST-PRESSURE' |
'-1110' |
INSULATION-THICKNESS |
'INSULATION-THICKNESS' |
'-1111' |
MAIN-NS |
'MAIN-NS' |
'-1112' |
OPERATING-PRESSURE |
'OPERATING-PRESSURE' |
'-1113' |
OPERATING-TEMPERATURE |
'OPERATING-TEMPERATURE' |
'-1114' |
PID-DRAWING-NUMBER |
'PID-DRAWING-NUMBER' |
'-1115' |
LINE-ID |
'LINE-ID' |
'-1116' |
ALT-DESIGN-PRESSURE |
'ALT-DESIGN-PRESSURE' |
'-1117' |
ALT-DESIGN-TEMPERATURE |
'ALT-DESIGN-TEMPERATURE' |
'-1118' |
DESIGN-CODE |
'DESIGN-CODE' |
'-1119' |
FLUID-PHASE |
'FLUID-PHASE' |
'-1120' |
FROM |
'FROM' |
'-1121' |
HANDOVER-SUBSYSTEM-ID |
'HANDOVER-SUBSYSTEM-ID' |
'-1122' |
NDT-REQUIREMENT |
'NDT-REQUIREMENT' |
'-1124' |
PID-REVISION |
'PID-REVISION' |
'-1125' |
PROCUREMENT-WORK- |
'PROCUREMENT-WORK- |
'-1126' |
STRESS-CATEGORY |
'STRESS-CATEGORY' |
'-1127' |
STRESS-PACKAGE |
'STRESS-PACKAGE' |
'-1128' |
TEST-MEDIUM |
'TEST-MEDIUM; |
'-1129' |
TO |
'TO' |
'-1130' |
PWHT-REQUIREMENT |
'PWHT-REQUIREMENT' |
'-1131' |
SEQUENCE-NUMBER |
'SEQUENCE-NUMBER' |
'-1132' |
CONSTRUCTION-WORK- |
'CONSTRUCTION-WORK- |
'-1134' |
ATTRIBUTE0- |
'ATTRIBUTEn' |
'-600:-699' |