Controls which center-of-gravity calculations are performed for wet (full) pipe. Calculated values can then be output on the drawing using text positioning facilities or output in a Weight/Center of Gravity summary report.

  • Not Required performs no center-of-gravity for wet pipe

  • Calc C of G calculates center-of-gravity for wet pipe.

  • Calc C of G with Insulation calculates center-of-gravity for insulated wet pipe.

  • Calc C of G with and without Insulation calculates center-of-gravity for wet pipe and insulated wet pipe.

Defines:

Option Switch - 82, Pos 5
I-Configure - Supplementary.CentreOfGravity.ForWetPipe