Controls whether output components are grouped by cut piece.
Select the check box to output components to the report file by cut piece. This is the default setting. To suppress this grouping so that each component has its own entry in the report file, clear the check box.
Defines:
Option Switch - N/A
I-Configure - Supplementary.NeutralFile.OutputCutPieces
An example is the component grouping Pipe-Pulled Bend-Pipe. Because these three components form a single cut piece, only one entry is written to the Neutral report file if Output Cut Pieces is selected. If Output Cut Pieces is not selected, three entries are written to the report file: one for each component.