You can set the data type options for the From2/To2, From3/To3, From4/To4, From5/To5 size ranges so that the cells for specification items support both numerical and character values, or just numerical values.
For non-template specifications, these options are available on the Cover page.
For template specifications, these options are not available; the From/To values are populated from the NPD values.
Set character options for a specification
-
Click SRD > XS20 Spec > XS2020 Spec Editor.
-
Select Specification Types/Spec Header/ Short Codes/Spec Item from the list in the tree view.
-
Open a non-template specification.
-
On the Cover page, click Open for edit .
-
Select the data type options as needed.
-
Click Save .
For example, if you select Numbers and characters in the From 2/To 2 box, the From 2/To 2 cells on the Components page can have either numerical or character data.