You can place two different drawing identifiers on the pipeline:
-
Client-Drawing-Identifier
-
Pipeline-Drawing-Identifier
-
All drawing identifiers are output using the text position facility, which you set up using ISOGEN Configuration in I-Configure.
-
I-Configure uses the following attribute names to text position each drawing identifier:
-
Pipeline-Drawing-Number uses PIPELINE-DRAWING-SEQUENCE-NUMBER.
-
Client-Drawing-Identifier uses CLIENT-DRAWING-IDENTIFIER.
-
-
Drawing identifiers are not usually output on the isometric drawing as a message on the component to which they are attached. However, you can configure the software to do so by setting AText ID -476 (default is Blank) to a suitable text string.
-
The same text string is used for all identifiers.
What do you want to do?
-
Place a Spool-Drawing-Number information item