Message
Assembly connection is missing a relation to the supported members end port.
Severity
Crucial.
Detailed Description
The relationship between the supported member part and the assembly connection does not exist. This relationship provides the proper compute order so that plate parts get generated after a cut operation occurs.
Possible Cause
Unknown.
Possible Impacts
Typically, plate parts will not appear at the correct location for gusset and corner-gusset type assembly connections.
What You Should Do
The assembly connection needs to be removed and re-created.
-
Ask your database administrator to back up the model.
-
Supply all information possible that may have led to this situation, and submit this information along with the backup to Intergraph Process, Power & Marine Support.
-
Open the model.
-
Locate the offending assembly connection, and delete it from the model.
-
Re-create the assembly connection through the normal create assembly connection process.