Analysis Model has more than one load combination folder - Intergraph Smart 3D - Administration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
11 (2016)

Message

Analysis Model has more than one load combination folder.

Severity

Crucial.

Detailed Description

Analysis Model has more than one load combination folder.

Possible Cause

If two or more load combination folders exist under a single analysis model, the relationship between the load combination folder and its analysis model is not accessible. Failure to access this folder will not be detected when a new load combination is created, resulting in the creation of a second load combination folder.

Possible Impacts

During the operation of exporting the analysis model, the software may fail to detect that the load combinations under the additional folders are actually associated to the analysis model. The software will not export these load combinations to the analysis export file.

What You Should Do

The only solution to resolve this situation is to remove your analysis model, which unfortunately will remove all your boundary conditions. You can accomplish this task by completing the following procedure:

  1. Copy your load combinations to the catalog.

  2. Delete your analysis model.

  3. Re-create your analysis model.

  4. Paste from catalog your copied load combinations into your new analysis model load combination folder.

  5. Re-define your boundary conditions.