Analysis WSE folder has no parent - Intergraph Smart 3D - Administration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
11 (2016)

Message

Analysis WSE (Workspace Explorer) folder has no parent.

Severity

Crucial.

Detailed Description

A boundary condition, load combination, or member folder does not have an associated Analysis Model. Or, a load case folder or unassigned members folder does not have an association to the model.

Possible Cause

It is not known what may have caused this situation. Normally, when an Analysis Model or plant or ship model is removed, the folders are removed too. The permissions on the parent Analysis Model or plant or ship model will match those of its associated folders; therefore, one cannot delete the parent of an analysis folder without deleting the folders themselves.

Possible Impacts

The folder and its contents are orphaned and will not be visible in any of the provided views. These folders have no parents; therefore, they cannot be loaded into the workspace and will not affect any of the analysis operations including export.

What You Should Do

Use the Clean Database custom command to remove this folder.

  1. Ask your database administrator to back up the model.

  2. Supply all information possible that may have led to this situation, and submit this information along with the backup to Intergraph Process, Power & Marine Support.

  3. Using the Clean Database custom command, remove this folder.