Plate System does not have Molded Conventions defined - Intergraph Smart 3D - Administration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
11 (2016)

Message

Plate System does not have Molded Conventions defined.

Severity

Crucial.

Detailed Description

The Molded Conventions are not set on a Root Plate System.

Possible Cause

Unknown.

Possible Impacts

Plates and Stiffeners may fail during processing. This situation could affect Stiffener orientation and properties controlled by the default values for molded conventions.

What You Should Do

  1. Select the Root System, and edit the Molded Conventions on the property page.

  2. Re-run the Check Database Integrity custom command to verify that this error has been fixed.