Message
Frame connection missing its reference collection relation to the member system.
Severity
Crucial.
Detailed Description
A frame connection is not related to its parent member system.
Possible Cause
Unknown.
Possible Impacts
A number of problems will most likely occur; for example, you will be unable to graphically select the frame connection to get to the end of a member system.
What You Should Do
The frame connection needs to be removed and recreated.
-
Ask your database administrator to back up the model.
-
Supply all information possible that might have led to this situation, and submit this information along with the backup to Hexagon PPM Support.
-
Open the model.
-
Locate the offending frame connection, and delete it from the model.
-
Select the member part, and then click the member End on the member ribbon to re- create the frame connection.
-
Change the frame connection type back to the original connection type, and graphically select the supporting member to complete the frame connection modification.