PlateBound_AE / PlateCutOut_AE PG does not match with Plate System PG - Intergraph Smart 3D - Administration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
11 (2016)

Message

PlateBound_AE / PlateCutOut_AE PG does not match with Plate System PG.

Severity

High.

Detailed Description

The PlateBound_AE / PlateCutOut_AE permission group does not match the Plate System permission group.

Possible Cause

Unknown.

Possible Impacts

You cannot manipulate the object itself or other objects related to it.

What You Should Do

  1. Ask your database administrator to back up the model.

  2. In the software, click Tools > Custom Commands, and run the Clean Database custom command.

  3. Select the object(s) to be repaired.

  4. Click Clean Now.

  5. Re-run the Check Database Integrity custom command and the DBIntegrity report.

  6. If the object is still posted, contact Smart 3D Support.