Calculate internal pipe diameter at flow temperature:
-
Calculate correction factor for steam quality (for liquid, water, and steam, Fs=1):
-
Calculate scale reading factor:
-
Calculate differential pressure at normal flow rate:
-
Calculate pipe Reynolds number at normal flow rate:
-
Checking for critical flow.
-
Liquid/Water case:
-
If then the flow is critical.
-
-
Gas/Steam case:
-
For Venturi tubes:
-
For other restriction devices:
-
Calculate critical pressure ratio and define whether the flow is crtiical:
If then the flow is critical. If not, the flow is sub-critical.
-
-
-
Calculate b - ratio.
Case A Liquid/Water - critical flow
-
Calculate DP.
-
Calculate first estimate for b - ratio.
For Venturi tubes:
For other restriction devices:
-
Eps=1.
-
Calculate discharge coefficient. See the Appendix.
-
Calculate the new b - ratio.
-
Calculate the relative change in b - ratio.
-
Repeat steps d to f until the relative change in b - ratio is less than 0.0001.
-
Case B Gas/Steam - critical flow
-
Calculate gas expansion factor:
-
Calculate discharge coefficient. See the Appendix.
-
Calculate first estimate for b -ratio (Wn[1b/h], T[r], P1{psi-a}, D[in]:
-
Calculate orifice diameter at flow temperature:
-
Calculate bore Reynolds number at normal flow rate:
-
Calculate discharge coefficient. See the Appendix.
-
Calculate new b -ration in accordance with equations in step c.
Case C Sub Critical flow
-
First estimate for DPn:
-
Calculate first estimate for b - ratio.
-
For Venturi tubes:
-
For other restriction devices:
-
-
Calculate gas expansion factor (for liquids/water, Eps = 1)
-
For Venturi tubes and nozzles:
-
For orifice plates:
-
-
Calculate discharge coefficient. See the Appendix.
-
Calculate new b - ratio:
-
Calculate new DP.
-
For classical Venturi tube:
-
For Nozzles:
-
For orifice plates:
-
-
Calculate new DPn:
-
Calculate the relative change in DPn:
-
In Case C, repeat steps c to h until the relative change in the DPn is less than 0.0001.
8. Calculate orifice diameter at flow temperature:
9. Calculate orifice diameter at ambient temperature.
-
For Venturi tubes and nozzles:
-
For orifice plates: