Removes the stockpile item from the plant model completely. The item and its properties are deleted from the database and can no longer be placed in a drawing, regardless of the settings in Options Manager or Catalog Manager.
-
In case of a connector, this command is not available unless the partner connector is in one of the stockpiles.
-
For equipment components, the Engineering Data Editor view does not include a filter for Item Status = 'Active' (unlike other item types). Therefore the row corresponding to the item that was deleted from the stockpile is still shown in the view but becomes read-only after refreshing the Engineering Data Editor display; the item is removed from the display only when you close and reopen the drawing.
-
After deleting a stockpile item from the model, you can restore it to the stockpile (and then to the drawing) using the Edit > Undo command on the main menu, unless you have performed one of the actions that clears the Undo buffer. See Undo Command (Edit Menu).