Flush frame connection's supported member has invalid point-on relation to another member. Change connection to... - Intergraph Smart 3D - Administration

Intergraph Smart 3D Troubleshooting Reference

PPMProduct
Intergraph Smart 3D
PPMCategory_custom
Administration & Configuration
Version_S3D
12.x(2018)

Meaning: Inconsistent relations exist where the flush member is flush with one member system but related as point-on with a different member system. This error is an internal software failure.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Frame Connections.

  4. Select the frame connection in error.

  5. Select More from the Connection box on the ribbon.

  6. Click Flush in the tree view.

  7. Select the flush connection that you want (top, bottom, left, or right).

  8. Redefine the end location of the member.