Meaning: Failed to retrieve the output object of this updating operation. The output object is created when the operation is created and the semantic updates the information on the output object. Since this is an unexpected error, it could be a memory or database corruption problem. Therefore, the profile (stiffener or beam) part has not been created or updated.

Recovery:

  1. Restart the command.

  2. Restart the session.

  3. Reboot the computer to verify that all computer memory has been released.

  4. Verify that all inputs are good and are not on the To Do List or reported in the database integrity checks. Make any necessary corrections.

  5. If problem still exists, report steps taken to your support group.