No intersection is found between ‘Outfitting/Equipment Hole Aspect’ and ‘Structure(s)’. Please revise inputs. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
12 (2018)

Meaning: The thickness of the structure is more than the Hole Aspect geometry. Therefore, the outfitting physical geometry or the Hole Aspect geometry of the outfitting (if supported by outfitting) does not intersect with the structure.

Recovery: If the outfitting supports Hole Aspect geometry, ensure the outfitting's Hole Aspect geometry intersects the entire structure or the base port of the structure. If the outfitting does not support Hole Aspect geometry, ensure the outfitting physical geometry intersects the structure.