Seated frame connection is missing the supporting member system. Change connection to unsupported and then re-select the supporting member. - Intergraph Smart 3D - Administration

Intergraph Smart 3D Troubleshooting Reference

PPMProduct
Intergraph Smart 3D
PPMCategory_custom
Administration & Configuration
Version_S3D
12.x(2018)

Meaning: A seating member to support the seated member was not provided as an input to the seated frame connection. This error is an internal software failure where all the inputs were not provided to the seated frame connection.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Frame Connections.

  4. Select the frame connection in error.

  5. Select More from the Connection box on the ribbon.

  6. Click Seated in the tree view.

  7. Select the seated connection that you want (top, bottom, left, or right).

  8. Redefine the end location of the member.