Message
Assembly connection missing relation to supported member part end port.
Severity
Medium.
Detailed Description
The relationship between the assembly connection and the supported member end port does not exist.
Possible Cause
Unknown.
Possible Impacts
The assembly connection will not compute properly, so any trim or cut operation on the supported member will not occur.
What You Should Do
The assembly connection needs to be removed and re-created.
-
Open the model.
-
Locate the offending assembly connection, and delete it from the model.
-
Re-create the assembly connection through the normal create assembly connection process.