Message

Design Equipment has Invalid Range.

Severity

Normal.

Detailed Description

A Design Equipment with no children (no Shape or Standard Equipment) is not supposed to have any range stored in the CORESpatialIndex(range) table. The DB integrity scripts check to see if there is any Design Equipment with no children, but with an entry in the range table.

Possible Cause

Prior to Version 4.1, the design equipment range with no children was stored in the range table. This problem was fixed in V4.1, but existing data was not migrated. This script will report them in the DBIntegrity report.

Possible Impacts

  • This situation could cause problems in range calculations.

  • This situation places unnecessary entries in the range table.

What You Should Do

The entries in the range table must be deleted. There is currently no mechanism to trigger the script to fix this DB integrity problem using the Clean Database custom command.