Split connection has invalid inputs. Delete and replace. - Intergraph Smart 3D - Administration

Intergraph Smart 3D Troubleshooting Reference

PPMProduct
Intergraph Smart 3D
PPMCategory_custom
Administration & Configuration
Version_S3D
12.1(2019)

Meaning: The splice connection was expecting two members as input: one supporting member and one supported member. This error is a software failure.

Recovery: Delete the splice connection and re-apply the splice trim connection. If you have customizable code that places splice connections, review the code and verify that the inputs given are similar to the structure provided splice connection sample.

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Split Connections.

  4. Select the split connection in error.

  5. Click Delete .

  6. Click Place Split and place the split connection again.