Centerline frame connection was reverified and found to be invalid. Change connection to unsupported and then... - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
12.1 (2019)

Meaning: Re-verification of the axis collinear connection indicates that it was not established correctly. This is an internal software failure.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Frame Connections.

  4. Select the frame connection in error.

  5. Select More from the Connection box on the ribbon.

  6. Click Centerline in the tree view.

  7. Select the centerline frame connection to use.

  8. Redefine the end location of the member.