In the tree view, click Piping > Piping Specification > Model Rules > End Preparation Compatibility Rule.
-
Click the Insert Row Command to insert a blank row in the grid view.
-
In the End Prep 1 column, specify the first end preparation code to define a mating port.
-
In the End Prep 2 column, specify the second end preparation code to define a mating port.
The Mating Ports sheet in the Piping Specification.xls workbook corresponds to the End Preparation Compatibility Rule node. See Piping Reference Data.