Fitted connection has an invalid number of inputs. Delete and replace. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: The connected end of the supported member and the along position of the supporting member were expected as inputs, but the end port count was not two, resulting in incorrect placement of the fitted connection. This error is an internal software failure.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Member Assembly Connection.

  4. Select the assembly connection in error.

  5. Click Delete ICON Remove.

  6. Click Place Assembly Connection .

  7. Place a new assembly connection as needed.