Mitred connection has invalid inputs. Delete and replace. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: Incorrect mitered connection placement where either one of two members was not provided or one of two end ports was not provided as inputs into the construction/compute of the assembly connection, resulting in incorrect mitered connection placement. This is an internal software failure.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Member Assembly Connections.

  4. Select the assembly connection in error.

  5. Click Delete ICON Remove.

  6. Click Place Assembly Connection .

  7. Select the frame connection.

  8. Clear the By Rule option.

  9. Select More from the Type box.

  10. Select Member By Member Assembly Connection > Mitre Assembly Connection > MitreAsmConn_1.

  11. Click OK.

  12. Click Finish.