Minimum Pipe Length Violation - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: The pipe is shorter than the minimum pipe length defined in the piping specification's Minimum Pipe Length Rule for Random Length Pipe rule. For example, if the minimum pipe length for 6" pipe is 3" and the preferred minimum pipe length for 6" pipe is 4”, and the user creates a straight pipe feature that is 3” or less, a Minimum Pipe Length Violation entry is generated on the To Do List.

Recovery: Increase the length of the pipe to be more than the minimum required length, or decrease the minimum length value in the piping specification.