Seated frame connection is missing a required input. Change connection to unsupported and then re-select the supporting member. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: The seated frame connection expects two objects as input: a seated supported member and a seating supporting member. This error is an internal software failure where not all the inputs were provided to the seated frame connection.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Frame Connections.

  4. Select the frame connection in error.

  5. Select More from the Connection box on the ribbon.

  6. Click Seated in the tree view.

  7. Select the seated connection that you want (top, bottom, left, or right).

  8. Redefine the end location of the member.