Message

Mismatched relations

Severity

Normal

Detailed Description

The Can Rule is input to a Frame Connection whose Member System is not a contributing member of the Can Rule, or the Can Rule has a contributing member that has no Frame Connection in relation to the Can Rule.

Possible Cause

The can failed to compute correctly.

Possible Impacts

Unknown

What You Should Do

  1. Modify the can and remove the transverse member. Then add the transverse member back to the can.

  2. Run the fix script when it is available.