Assembly connection is missing one or more related axis ports - Intergraph Smart 3D - Administration & Configuration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
12.1 (2019)

Message

Assembly connection is missing one or more related axis ports.

Severity

Crucial.

Detailed Description

The identified assembly connection has a fixed number of relations that should exist between the assembly connection and the supported/supporting members. When this fixed number of relations is not as expected, this error occurs.

Possible Cause

Unknown.

Possible Impacts

It is highly probable that the assembly connection will not compute properly, so the cut or trim operation will not occur, and any generated plates will not be created.

What You Should Do

The assembly connection needs to be re-created.

  1. Ask your database administrator to back up the model.

  2. Supply all information possible that may have led to this situation, and submit this information along with the backup to customer support. You can find support information on our web site at Hexagon Customer Support.

  3. Open the model.

  4. Locate the offending assembly connection, and delete it from the model.

  5. Re-create the assembly connection through the normal create assembly connection process.