Hull Plate System does not have Shell Molded Conventions defined - Intergraph Smart 3D - Administration

Intergraph Smart 3D Database Integrity Administration

PPMProductFamily
3D Design and Visualization
PPMProduct
Intergraph Smart 3D
PPMCategory
Administration
Version_S3D
12.1(2019)

Message

Hull Plate System does not have Shell Molded Conventions defined.

Severity

Crucial.

Detailed Description

The shell molded conventions are not specified for a plate system of type Hull.

Possible Cause

Unknown.

Possible Impacts

Plates and stiffeners might fail during processing. This situation can affect stiffener orientation and properties controlled by the default values for molded conventions.

What You Should Do

  1. Select the root system, and edit the shell molded conventions on the Properties dialog box.

  2. Re-run the Check Database Integrity custom command to verify that this error has been fixed.