In the tree view, click Piping > Piping Specification > Piping Materials Classes.
-
In the Piping Materials Classes branch, open a specification and click Piping Materials Class Rules > Preferred Tap End Stud Bolt Length Rule.
-
Click the Insert Row Command to insert a blank row in the grid view.
-
In the Bolt Diameter From column, enter the bolt diameter lower bounds for which to specify a preferred length.
-
In the Bolt Diameter column, enter the bolt diameter upper bounds for which to specify a preferred length.
-
In the Bolt Diameter Increment column, enter the value by which to increment the bolt diameter.
-
In the Material Grade column, enter the material grade code for the bolt.
-
In the Preferred Bolt Length From column, enter the preferred bolt length lower bound for this bolt diameter and material grade.
-
In the Preferred Bolt Length To column, enter the preferred bolt length upper bound for this bolt diameter and material grade.
-
In the Preferred Bolt Length Increment column, enter the value by which to increment the preferred bolt length.
-
Click the Save Command .
The Preferred Tap End Stud Bolt Length sheet in the workbook corresponds to the Preferred Tap End Stud Bolt Length Rule node. See Piping Reference Data.