You must use an external database to complete these steps.
-
Click Setup on the Process Lines panel.
-
Select System On (Dynamic Size/Spec).
-
Add categories and separators as needed.
-
Select a category, and then assign a value in the Default value box.
-
Click OK.
-
Click Pumps .
-
Select a pump, and then click OK.
-
Click to place the pump in the drawing, and then click to place the tag information.
-
Click Vessel , and add a vessel in the drawing.
-
Select a vessel, and then click OK.
-
Click to place the vessel in the drawing, and then click to place the tag information.
-
Click Major Primary , and draw a line between the pump and the vessel.
You can change the color of the major primary line in the Layers.
-
Click Tag Line .
-
Select the major primary line.
-
Click to place the tag.
-
Click to rotate the tag.
The software places the tag, and adds the line number to the Tag value.
-
Double-click the process line.
-
Click Process Data.
The Process From, Process To, Actual From, and Actual To boxes display the correct values.